Core terminology
Sampling rateHow many discrete measurements are taken per second. CD audio uses 44.1 kHz.
Nyquist frequencyHalf the sampling rate. It is the upper frequency boundary of the representable baseband: 22.05 kHz for 44.1 kHz sampling.
Nyquist rateThe minimum ideal sampling rate required for a target maximum frequency: 2 × fmax. A 20 kHz tone therefore requires at least 40 kHz in the ideal theorem.
AliasingFrequencies above the Nyquist frequency fold into the baseband and appear as incorrect lower frequencies.
fN = fs/2 · fs,min = 2fmax